| Modifier and Type | Class and Description |
|---|---|
| public static class | LowLevelMonitorConfigurationAPI.MC_TIMING_REPORT
Contains information from a monitor's timing report. |
| public static enum | LowLevelMonitorConfigurationAPI.MC_VCP_CODE_TYPE
Describes a Virtual Control Panel (VCP) code type. |
| Modifier and Type | Field and Description |
|---|---|
| public WinDef. | bTimingStatusByte
Timing status byte. |
| public WinDef. | dwHorizontalFrequencyInHZ
The monitor's horizontal synchronization frequency in Hz. |
| public WinDef. | dwVerticalFrequencyInHZ
The monitor's vertical synchronization frequency in Hz. |
| Access | Constructor and Description |
|---|---|
| public |
| bTimingStatusByte | back to summary |
|---|---|
| public WinDef. Timing status byte. For more information about this value, see the Display Data Channel Command Interface (DDC/CI) standard. | |
| dwHorizontalFrequencyInHZ | back to summary |
|---|---|
| public WinDef. The monitor's horizontal synchronization frequency in Hz. | |
| dwVerticalFrequencyInHZ | back to summary |
|---|---|
| public WinDef. The monitor's vertical synchronization frequency in Hz. | |
| MC_TIMING_REPORT | back to summary |
|---|---|
| public MC_TIMING_REPORT() | |
| Modifier and Type | Class and Description |
|---|---|
| public static class | LowLevelMonitorConfigurationAPI.MC_VCP_CODE_TYPE.ByReference
Defines a Reference to the enum |
| Modifier and Type | Field and Description |
|---|---|
| public static final LowLevelMonitorConfigurationAPI. | MC_MOMENTARY
Momentary VCP code. |
| public static final LowLevelMonitorConfigurationAPI. | MC_SET_PARAMETER
Set Parameter VCP code. |
| Access | Constructor and Description |
|---|---|
| private |
| Modifier and Type | Method and Description |
|---|---|
| public static LowLevelMonitorConfigurationAPI. | |
| public static LowLevelMonitorConfigurationAPI. |
| MC_MOMENTARY | back to summary |
|---|---|
| public static final LowLevelMonitorConfigurationAPI. Momentary VCP code. Sending a command of this type causes the monitor to initiate a self-timed operation and then revert to its original state. Examples include display tests and degaussing. | |
| MC_SET_PARAMETER | back to summary |
|---|---|
| public static final LowLevelMonitorConfigurationAPI. Set Parameter VCP code. Sending a command of this type changes some aspect of the monitor's operation. | |
| MC_VCP_CODE_TYPE | back to summary |
|---|---|
| private MC_VCP_CODE_TYPE() | |
| valueOf | back to summary |
|---|---|
| public static LowLevelMonitorConfigurationAPI. | |
| values | back to summary |
|---|---|
| public static LowLevelMonitorConfigurationAPI. | |
| Access | Constructor and Description |
|---|---|
| public | |
| public | ByReference(LowLevelMonitorConfigurationAPI.
the value valueInstantiates a new reference. |
| Modifier and Type | Method and Description |
|---|---|
| public LowLevelMonitorConfigurationAPI. | |
| public void |
| ByReference | back to summary |
|---|---|
| public ByReference() Create an uninitialized reference | |
| ByReference | back to summary |
|---|---|
| public ByReference(LowLevelMonitorConfigurationAPI. Instantiates a new reference.
| |
| getValue | back to summary |
|---|---|
| public LowLevelMonitorConfigurationAPI. Gets the value.
| |
| setValue | back to summary |
|---|---|
| public void setValue(LowLevelMonitorConfigurationAPI. Sets the value.
| |